What is recorded for DPSB613ED
GE DPSB613ED — Energy source: Electricity.
GE DPSB613ED
Clothes dryer · US market · 44 owner topics
Specifications for DPSB613ED with owner checks for this product design. Use the matching manual for control sequences and replacement parts.
Specifications & model details
GE DPSB613ED — Energy source: Electricity.
Estimate dryer operating cost from real household loads, exact model data, and local fuel prices. Keep gas and electric charges separate and show assumptions clearly.
Category & symptom guidance
A useful estimate begins with the dryer’s exact model and fuel configuration. Vented electric, vented gas, condenser, and heat-pump dryers do not share one comparable consumption figure. For gas, there is a gas cost plus a smaller electrical component; for resistance electric, the heat load is primarily electricity. A heat-pump dryer’s lower electricity demand and longer cycle pattern should be represented by its own published data rather than borrowing a vented model’s rating.
LG’s DLEX4000/DLGX4001 specification sheet lists CEF values for electric and gas versions, but CEF is not a direct price-per-cycle value. Use a DOE or manufacturer estimate that states its assumptions, or use an energy meter or utility data appropriate to the machine and installation. Preserve the source and units next to each input so a later estimate remains auditable.
If a trustworthy source gives cost per load, multiply that figure by the number of loads in the period. For example, annual dryer cost equals cost per load × loads per week × 52. If the source gives energy per load, multiply by your electricity price per kilowatt-hour for electric use. For gas, convert the source’s gas quantity to the unit on your bill, multiply by the gas rate, and add electricity used by the appliance if the data provides it.
Do not silently mix a national average rate with a local bill rate or add taxes twice. Some utility bills include delivery charges that change with usage; others include fixed monthly charges that do not. Use the marginal charge that would rise with dryer use, and label any approximation. If the bill has time-of-use pricing, use the rate for the hours when drying normally occurs.
When consumption is stated per cycle, use: annual variable cost = energy per cycle × cycles per year × energy rate. For a gas dryer with both gas and electricity figures, calculate two subtotals and add them. If a published figure is annual consumption instead, multiply annual consumption by your rate only when its usage assumptions resemble your household; otherwise scale by load count if the source supports that adjustment.
For example, if your own source reports 3.2 kWh per cycle, you run 4 cycles weekly, and the relevant rate is 0.25 currency units per kWh, the electricity part is 3.2 × 4 × 52 × 0.25 = 166.40 per year. This is an arithmetic illustration, not a dryer performance claim. Replace every sample number with exact model and household inputs.
A utility bill rarely isolates a dryer’s contribution from cooking, water heating, cooling, and other equipment. A before-and-after bill comparison is especially weak when the season, occupancy, or rate changed. If you use a whole-home meter, compare multiple similar weeks and account for other major usage changes. A plug meter is only appropriate where the dryer’s electrical connection and instrument rating permit it; most full-size electric dryers are not measured by ordinary plug-in meters.
For gas models, a gas meter reading includes every gas appliance unless the dryer can be isolated through a reliable method. Do not alter gas piping or electrical connections to obtain a measurement. If direct measurement is not practical, use model-specific standardized data and a transparent load count instead of guessing from the whole bill.
A running-cost estimate excludes purchase price, financing, installation, vent work, maintenance, and repair. To compare replacements, calculate the energy difference for the same annual load count, then compare that annual difference with the extra upfront amount. A simple payback estimate is extra installed cost ÷ annual energy savings. This is only a screening calculation: it does not discount future money, include repairs, or predict how long either machine will last.
Enter actual written quotes for installation, vent correction, and disposal. Do not substitute generic market averages, because location and site conditions can dominate. A heat-pump model may avoid a vent route but need different condensate handling; a gas-to-electric change may require electrical work. Include those line items only when they apply to the specific home and option.
A good estimate shows a low, typical, and high use case without pretending to predict exact bills. Vary the number of loads or the rate, not the model’s technical performance, unless you have evidence for that variation. Keep gas and electricity subtotals visible, and identify whether you counted dryer-only energy or total household charges.
For a household deciding between two machines, the most useful output is the annual cost difference at its own usage level. Include the source date and the exact model variant; rates and product specifications can change. If the published source does not identify the fuel, test cycle, or units, treat it as insufficient for a numerical comparison and seek a better-matched source.
It supports a standardized efficiency comparison but not a direct bill estimate.
The appliance also uses electricity for operation, which may affect the total cost.
No. The bill includes other appliances and often fixed charges. Use the marginal energy rate and dryer-specific consumption data.
Only for a broad illustrative estimate. Use your current marginal rate for a household decision and state the date and assumptions.
These sources support the shared guide. Exact model specifications and matched family procedures have their own sources above.
Owner guidance by Specs & Parts, drafted with GPT-6 Luna. Sources and scope.